The following info and data is provided "as is" to help patients around the globe.
We do not endorse or review these studies in any way.
Brief Title: Short-term Implanted Electrodes Following Regenerative Peripheral Nerve Surgery for Improving Prosthetic Limb Control Signals
Official Title: Short-term Implanted Electrodes Following Regenerative Peripheral Nerve Surgery for Improving Prosthetic Limb Control Signals
Study ID: NCT03260400
Brief Summary: The device, a bipolar percutaneous intramuscular electromyography electrode, is intended for use in upper-limb amputation patients who have received the regenerative peripheral nerve interface surgical procedure, in order to enable the use of advanced prosthetic arms and hands.
Detailed Description: This is a single center, 10 subject early feasibility study in which the primary objective is to ensure the safety of percutaneous intramuscular electrodes implanted in surgically-created RPNI constructs (free muscle grafts attached to the amputated nerves) in subjects with upper limb amputation. The secondary objectives are to assess the efficacy of the electrodes in recording electromyographic signals from the RPNI grafts and in delivering electrical stimulation to the RPNI grafts to evoke sensory percepts. This study will enroll people who have had upper limb amputations or are planning to have upper limb amputations. Each participant who does not already have RPNI grafts at the time of enrollment will have RPNI grafts implanted on branches or fascicles of nerves of the upper extremity. Several or all RPNI grafts will have a single bipolar electrode implanted in the muscle tissue, with the proximal end tunneled to a percutaneous exit point on the residual limb. Additional electrodes may be placed in innervated muscles in the residual limb, in order to provide a control comparison as well as to provide additional input during prosthesis control experiments. Electrodes will remain implanted for up to 7 years, with a minimum of 2 study visits per month to perform prosthesis control and sensory feedback experiments. Study endpoint will be assessed at a minimum of once per month while electrodes remain implanted. After a maximum of 7 years, electrodes will be explanted and the study ended after a 1 week follow-up. The results of this study will inform the final design of the electrodes to be implanted long-term in RPNI grafts to provide an increased number of degrees of freedom for prosthetic control and sensory and proprioceptive feedback. This will drastically improve the functionality of the prosthesis, enhance the sense of embodiment of the prosthesis itself, and enable future investigation of a fully-implanted (non-percutaneous) prosthesis control system.
Minimum Age: 22 Years
Eligible Ages: ADULT, OLDER_ADULT
Sex: ALL
Healthy Volunteers: No
University of Michigan, Ann Arbor, Michigan, United States