Spots Global Cancer Trial Database for Real-time Diagnosis and Visualization of Tumor Margins in Excised Breast Specimens Using Zenith FLIM Diagnostics

The following info and data is provided "as is" to help patients around the globe.
We do not endorse or review these studies in any way.

Trial Identification

Brief Title: Real-time Diagnosis and Visualization of Tumor Margins in Excised Breast Specimens Using Zenith FLIM Diagnostics

Official Title: Real-time Diagnosis and Visualization of Tumor Margins in Excised Breast Specimens Using Zenith FLIM Diagnostics

Study ID: NCT04683120

Study Description

Brief Summary: Our investigational team has developed a technology to visualize the operative margins in 'real time,' in other words during the operation while the patient is still on the table. While different surgeons use different operative techniques, our technique involves removing the main lumpectomy specimen, marking two of its borders with suture to orient the specimen for correct pathologic evaluation. The FLIM (Fluorescent Lifetime Imaging Microscopy) technique can differentiate between cancerous and noncancerous specimens using a complex algorithm that essentially utilizes a definitive delta between the metabolic activities of diseased and non-diseased tissue. The research coordinator along with the surgeon will be able to insert the lumpectomy specimen followed by the 6 shaved margins (one by one) in a matter of minutes once the specimens have been resected. To be clear, the FLIM analysis will be taking place in- vitro. The device is invitro test and would be tested against the gold standard the pathologist biopsy. FLIM analysis by the surgeon will not take more than several minutes, therefore not adding any significant time for patient to be under anesthesia. All specimens will be removed from the patient's body prior to their evaluation by the FLIM technique. Our team will not be making decisions based on FLIM analysis during this early phase of study. In other words, even if FLIM suggests a positive margin still exists in the body, our team will not act on these results by resecting additional tissue at this stage. FLIM margin results will be compared directly with pathology results for accuracy of the findings.

Detailed Description: The purpose of this study is to evaluate the effectiveness of the investigational Zenith FLIM Diagnostics imaging device that's modality is a direct support during lumpectomy cancer surgery to achieve the common goal of improving patient quality of life by decreasing rates of re-operation. The team is fully dedicated to bringing the Gold Standard in the operating room, enabling margin assessment, in real time, at the histological detail. Our operative technique involves removing the main lumpectomy specimen, marking two of its borders with suture to orient the specimen for correct pathologic evaluation. Next, we take 6 shave margins in all directions around the lumpectomy cavity (superior, inferior, medial, lateral, posterior, anterior) and anchor an orientation stitch at the far side of the margin, again, for pathologist to understand which side was farthest away from the lumpectomy specimen. The research coordinator along with the surgeon will be able to insert the lumpectomy specimen into the Zenith FLIM device followed by the 6 shaved margins (one by one) in a matter of minutes once the specimens have been resected. To be clear, the Zenith FLIM analysis will be taking place in-vitro. The machine will be placed a good distance from the patient, in an ante-room, and does not require sterility. Of course, if the surgeon breaks sterility while handing off the specimens for FLIM analysis, he or she will have to re-sterilize as would be standard if sterile conditions are broken for any other reasons (having to re-scrub because sterility is broken is a common procedure). Once the specimens are placed in the Zenith FLIM, the specimens will no longer be sterile, but there is no need to maintain sterility of the specimens once they are in-vitro. In fact, even in the absence of Zenith FLIM analysis, once the specimens are placed in cups for pathologic evaluation, they are no longer sterile. In other words, loss of sterility of the specimen is a necessity of the operation regardless of Zenith FLIM analysis. The device is an in-vitro test and would be tested against the gold standard: the pathologic evaluation of resected tissue. The test results would not be used for any diagnosis. Neither the test nor the unit comes in contact with patients under any circumstance. The Zenith FLIM margin results will be compared directly with pathology. The effectiveness of the Zenith FLIM Diagnostics margin results will be compared directly with pathology and evaluated in this study.

Eligibility

Minimum Age: 18 Years

Eligible Ages: ADULT, OLDER_ADULT

Sex: FEMALE

Healthy Volunteers: Yes

Locations

Laser LabCorp, New York, New York, United States

Contact Details

Name: Brad Schoengood

Affiliation: Laser LabCorp

Role: STUDY_CHAIR

Useful links and downloads for this trial

Clinicaltrials.gov

Google Search Results

Logo

Take Control of Your Skin and Body Changes Today.

Try out Spots for free, set up only takes 2 mins.

spots app storespots app store

Join others from around the world: