Spots Global Cancer Trial Database for Positioning and Tracking the Prostate During External Beam Radiation

The following info and data is provided "as is" to help patients around the globe.
We do not endorse or review these studies in any way.

Trial Identification

Brief Title: Positioning and Tracking the Prostate During External Beam Radiation

Official Title: Beacon® Transponder Implantation and Localization in the Prostate

Study ID: NCT00123838

Conditions

Prostate Cancer

Study Description

Brief Summary: The purpose of this study is to evaluate a non-ionizing electromagnetic method to align the prostate treatment site for radiation therapy and to monitor its position throughout radiation therapy delivery. The clinical study involves using an investigational device, the Calypso® 4D Localization System, and requires permanent implantation of three small sensors called Beacon® transponders in the prostate.

Detailed Description: The goal for prostate radiation therapy is to give a high dose of radiation to the prostate and a minimal dose to the healthy tissue around the prostate. It is well known that the prostate moves slightly within the pelvis and that its position varies a few millimeters from day to day. There are several methods used to position the body and the prostate accurately at the beginning of each radiation therapy session. One of the standard methods is to permanently implant small markers (gold spheres or cylinders) in the prostate and use x-rays in the radiation therapy treatment room to determine whether the markers are in the correct position. If the markers are in the correct position, then the assumption is that the prostate also is in the correct position. If the markers are not in the correct position on the x-ray, then the table that the patient lies on can be shifted so that the markers are in the right place. In this study the Beacon® transponder will be used in place of the standard gold marker. During the radiation therapy visits, the patient position in the treatment room will be corrected using the Beacon transponder with an investigational system, called the Calypso® 4D Localization System. The Calypso system consists of a flat panel, placed over the pelvis and connected to a computer, which monitors the position of the Beacon transponders within the prostate. During five radiation therapy appointments and one extra visit, the position of the markers in the prostate will be confirmed with x-rays. The Beacon transponder is a small glass cylinder that contains a tiny electrical circuit. The glass vial is completely sealed and separates the internal components (i.e., the electrical circuit) from the rest of the body. The glass vial is approximately one-third of one inch long and one-tenth of one inch in diameter. Three Beacon transponders will be implanted in the prostate. They will be permanently implanted.

Eligibility

Minimum Age: 18 Years

Eligible Ages: ADULT, OLDER_ADULT

Sex: MALE

Healthy Volunteers: No

Locations

Scottsdale Healthcare - Osborn, Scottsdale, Arizona, United States

Sharp Memorial Hospital, San Diego, California, United States

M.D. Anderson Cancer Center Orlando, Orlando, Florida, United States

The Nebraska Medical Center, Omaha, Nebraska, United States

The Cleveland Clinic, Cleveland, Ohio, United States

Contact Details

Name: Lisa Levine, Ph.D.

Affiliation: Varian, a Siemens Healthineers Company

Role: STUDY_DIRECTOR