The following info and data is provided "as is" to help patients around the globe.
We do not endorse or review these studies in any way.
Brief Title: Endoscopic Full Thickness Resection in the Lower GI Tract With the "Full Thickness Resection Device"
Official Title: Endoscopic Full Thickness Resection in the Lower GI Tract With the "Full Thickness Resection Device"- A Prospective Multicenter Trial
Study ID: NCT02362126
Brief Summary: Observational prospective multicenter study to investigate efficacy and safety of endoscopic full thickness resection in the lower GI tract using a novel over-the-scope full thickness resection device.
Detailed Description: The FTRD ("Full Thickness Resection Device", Ovesco Endoscopy, Tübingen, Germany) is an over the scope device consisting of a transparent cap with a preloaded monofilament snare and and a 14 mm modified Over-the-scope Clip. The device is CE marked for full thickness resection in the lower GI tract. The study was designed to investigate efficacy and safety of this device for full thickness resection of colorectal lesions.
Minimum Age: 18 Years
Eligible Ages: ADULT, OLDER_ADULT
Sex: ALL
Healthy Volunteers: No
Klinikum Ludwigsburg, Ludwigsburg, Baden-Württemberg, Germany
Name: Karel Caca, MD, PhD
Affiliation: Klinikum Ludwigsburg, Department of Gastroenterology
Role: STUDY_CHAIR
Name: Arthur R Schmidt, MD
Affiliation: Klinikum Ludwigsburg, Department of Gastroenterology
Role: PRINCIPAL_INVESTIGATOR